Transfer unit Bizhub C250

How do you replace the Transfer unit on the Bizhub C250?

  • 1 more comment 
  • Anonymous Mar 11, 2009

    what screws? and isn't there a block lever I have to pull down? Not sure where this is.

  • Giamma Giamma May 11, 2010

    Have you got a new trasfert belt unit? or you want to reset life of actual trasfert belt?

  • Anonymous Mar 24, 2013

    i want to reset life

×

2 Answers

Anonymous

Level 1:

An expert who has achieved level 1.

Mayor:

An expert whose answer got voted for 2 times.

  • Contributor 1 Answer
  • Posted on Feb 14, 2009
Anonymous
Contributor
Level 1:

An expert who has achieved level 1.

Mayor:

An expert whose answer got voted for 2 times.

Joined: Feb 14, 2009
Answers
1
Questions
1
Helped
1890
Points
6

Reset life of actual transfer

  • Anonymous Feb 14, 2009

    To replace, remove the 2 screws holding the unit into the case, carefully remove old unit and very carefully install the new one, be careful not to scrap the face of the new unit, reinstall the two screws and close everything up and start

×

Ben

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Expert 108 Answers
  • Posted on Jun 22, 2017
Ben
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: May 12, 2010
Answers
108
Questions
0
Helped
89456
Points
277

The "Life Counter" of the transfer belt is reset by a fuse in the new transfer belt. If you just want to reset the life counter you have to remove the transfer belt, locate the fuse behind a housing on the front right side, and replace the glass fuse. Once you reinstall the old belt with the new fuse the counter will reset.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Bizhub c250 replace filter

which filter one comes with the transfer belt the other with black image unit and or toner

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

2helpful
1answer

What is error p-21 of konica minolta bizhub c250?

P-21: Color regist test pattern failure




1 Wipe clean the surface of the transfer belt with a soft cloth, if it is dirty.
2 Change the image transfer belt unit if the transfer belt is damaged.
3 Change the PH unit.
4 Change PRCB.

run halftone prints from service mode to isolate which color is having an issue.

check all image units


3helpful
1answer

My Konica Minolta bizhub C250 says replace transfer unit. I have looked for this part and can find nothing listed as a Transfer Unit. There are many parts listed but none specifically says Transfer Unit....

I am sending you this link because A) they have all the parts listed including part numbers and pictures. They are also a good source for parts and supplies. You might find one cheaper on the net tho. Also keep in mind that these transfer belt units are resettable by replacing a $5 fuse in the unit. If you have a local independant repair guy, maybe he can research this and reset your existing unit as they will usually go at least 2 cycles. I reset a dozen or more of these units per year for my customers.
http://www.precisionroller.com/search.php?q=minolta+c250+transfer+
Thank You for using Fixya.
WheatlandServices
0helpful
1answer

My konica Minolta Bizhub c250 is printing an image that is faded in sections and reprints very subtly in other sections where it should be white space. Can you help me fix this problem?

It could be either your image transfer belt that needs replacing, or your fuser unit. Check the transfer belt first, that's the most common cause for "ghost images"
1helpful
1answer

Konica Minoltra Bizhub C250 Malfunction detected C-2451 This message I got after I changed fuse on transfer unit. How to solve it, or at least what this error code means?

hi, from the service manual:
C2451:
Item:
Transfer Cleaner Unit New
Article Release

Description:
A new installation is not detected when a new
Transfer Cleaner Unit (Image Transfer Belt Unit) is
installed.

for the solution, SM says you should try refitting Transfer Cleaner Unit(misplacing could occur) or change the PWB-M board.


2helpful
2answers

Where can I get instructions on how to replace the transfer unit of my Bizhub C252?

Please visit the site http://www.resetkit.eu
There you can find how to reset your fusing unit and transfer kit unit for almost all Konica Minolta MFP's and printers, Bizhub C252 included.
You don't need to replace it, you can just reset it and save a lot of money.

Reset your Toners and Imaging units for Minolta Bizhub and CF series.
http://www.chipreset.eu
14helpful
4answers

Transfer unit on bizhub C250

its not so hard, open side door, remove 2 screws, and pull out the transfer unit gently. and reinstall new TBU. BE VERY CAREFUL WITH NEW UNIT, DO NOT DAMAGE IT.
Not finding what you are looking for?

1,900 views

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7035 Answers

Cindy Wells

Level 3 Expert

6688 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...