Lee Ferriss Posted on Jul 26, 2017
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Where is fuel filter on ti7000lxr diesel generator

This is a tahoe diesel generator the oil is fine

1 Answer

sherlywang

Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

  • Master 428 Answers
  • Posted on Dec 09, 2019
sherlywang
Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Master:

An expert who has achieved Level 3.

Joined: Oct 20, 2017
Answers
428
Questions
0
Helped
198573
Points
1063

Ask your supplier to get more details. They is the OEM supplier of the diesel engine, so they can contact the diesel engine supplier. If you plan to purchase diesel generator set, please visit at https://starlightgenerator.en.made-in-china.com

3 Related Answers

Anonymous

  • 3 Answers
  • Posted on Jun 23, 2008

SOURCE: 2000 ford f250 super duty 4x4 7.3L diesel oil leak

The HPOP (high pressure oil pump) is right under the filter housing. There are 2 lines that distribute the oil to the cylinder heads. The o-rings on those fittings go out. Kit is available from Ford or International. You will need a special wrench to get to the fittings though.

Ad
harley9701ha

Bill

  • 424 Answers
  • Posted on Jun 25, 2009

SOURCE: 05 F-250, 6.0 Diesel, fuel filter

There are 2 fuel filters. One on the engine to the right of the oil filter. The other one is on the left frame rail . I hope this helps

Lawrence Oravetz

  • 10558 Answers
  • Posted on Mar 11, 2016

SOURCE: P6000s silent diesel generator Serviced the generator and filled the sump with 1.65L of 15w30 diesel oil the oil light keeps coming on when running what can cause it to come on? Jamie

The oil pump may not be working or the pressure sender may be bad.

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

1helpful
2answers
0helpful
1answer

Where is fuel filter on ti7000lxr tahoe diesel generator

The purpose of any diesel fuel filter is to remove foreign particles as well as water. The use of a suitable filtration system on diesel engines is a must to avoid damage to closely fitted injection pump and injector components. Filter's ability varies between the type and manufacturer. On diesel engines primary and secondary filters are used. The primary filter is capable of removing dirt particles down to 30 microns and the secondary filter between 10 to 12 microns. Secondary filters are available between 3 and 5 microns, which are used in severe service operations. The primary filter is usually located between the tank and the supply pump, the FWS is one type of the primary filters. The secondary filter between the supply pump and the injection pump.The basic working principle of fuel filter for diesel engine mentioned above is share by Jiangsu Starlight Electricity Equipment Co.,Ltd. Hope it is useful for all users. Besides, our company can provide a variety of specifications common from 3KW to 2500KW, automated, four-protection, automatic cut over, low noise and mobile and so on high quality, and the low energy consumption generator set so as to satisfy the customer all electric power demand. We can also satisfy the user different voltage, different frequency request, as well as many units and networking power supply system. More information about diesel generator at this link.
0helpful
1answer

I have a ti7000lxr generator starts up then shuts down.can you tell me where the fuel filter is.

Check and make sure you can see oil in the oil resivior.sounds like its low on oil.
0helpful
2answers

7.5 Onan Diesel RV generator cranks but will not start. Fuel is coming in, filters clean,oil good, glow plugs have power but it just cranks but will not start.

Visit the on-line store, know as reliable-store, they have the repair manuals. I'm sure you will get the solution of your problem. Best Manuals
0helpful
2answers

Why woun't my 6500 ransond generator start its a diesel

See id it is actually pumping fuel and if so see if the glow plugs are getting hot.
0helpful
2answers

Power generator will not start but will backfire

gasoline generator I suppose? re-clean your sparkplugs, check air-filter, and adjust your carb to run leaner. if its diesel lemme know
0helpful
1answer

Perkins DTA530E/1306CE87 250KVA generator set. Fault is when the unit is started it works for few minutes and the engine cuts off.

Maybe it causes by the following problems:

Fuel System Failure

1. Air in the fuel system
This is a common problem that a diesel generator fails to start normally.
Solution: Check whether the fuel oil pipe connector is loose or not, and ensure that the air is cleared from the fuel system. Loosen the bleed screw bolt on the diesel filter, and then use the manual oil pump to pump the fuel until the air bubble is gone.
2. Fuel Line Obstruction
Solution: Check whether the pipeline is smooth or not.
3. Fuel Filter Clogging
Solution: Clean the filter or replace the filter element
4. The Handle Position of Fuel Injection Pump Is Not Correct
Solution: The handle position should be pushed to no-load when starting the diesel generator set. Rotation speed is about 700-900r/min.
5. Fuel Injector Problem - Little fuel injection or fuel injection is not atomized
Solution: Remove the fuel injector, connect it to the high pressure oil pump, pry the fuel injection pump plunger spring and observe the spray condition. If necessary, wash the injection pump.
6. Oil Supply Problem - Oil transfer pump doesn't supply oil or the oil supply is brokenly.
Solution: Check whether the oil inlet pipe is leaked or not and the filter screen on the oil inlet pipe connector is blocked or not.
More information at article.
https://www.dieselgeneratortech.com/diesel-generators/why-diesel-generator-fail-to-start.html
0helpful
1answer

Lister Petter diesel generator that won't start

Here is some reasons and solutions for diesel generator fail to start:
1. There is air in the fuel systems
Check if the fuel line connection is loose and remove air from the fuel system. First unscrew the exhaust screws on the injection pump and the fuel filter and pump the oil with the hand pump until there are no bubbles in the spilled fuel. After, tighten the exhaust screw. Pump oil again, when there is return oil in the tubing, then tighten the hand pump. Loosen the nut of the high pressure tubing at one end of the injector, pry high injection pump plunger spring seat, when there is no bubble in the fuel out of the nozzle, spin the nut, then pry a few more times, so that each cylinder injector is filled with fuel.
2. The fuel line is blocked. Check if the pipeline is unimpeded.
3. Fuel filter block. Clean filter or replace filter.
4. Oil pump does not supply oil or intermittent oil supply. Check that the inlet pipe is leaking, and that the filter screen on the inlet joint is blocked. If no oil is supplied after removal, the intake pipe and oil pump shall be inspected.
More reasons and solutions, please see at:
https://www.dieselgeneratortech.com/generator-sets/Why-My-Diesel-Generator-Set-Fail-to-Start.html
Not finding what you are looking for?

321 views

Ask a Question

Usually answered in minutes!

Top Diesel Electrical Supplies Experts

Brad Brown

Level 3 Expert

19187 Answers

john h

Level 3 Expert

29494 Answers

ADMIN Andrew
ADMIN Andrew

Level 3 Expert

66967 Answers