Maytag Neptune - Recent Questions, Troubleshooting & Support
Maytag Neptune dryer displays 88 and won't start
our dryer just keeps running and doesnt not shut off after cycle is done. You have to unplug or open door for it to shut off. This is not a refurbished dryer we had bought brand new
2/12/2019 1:03:52 PM •
Maytag...
•
Answered
on Feb 12, 2019
Was drying a load of
Good morning to you
I would clean all the fluff from the dryer.
Enjoy your coffee
Kolbrun
1/25/2018 6:35:26 AM •
Maytag...
•
Answered
on Jan 25, 2018
Maytag MDE2400AYW Dryer Heating Elements not staying on
i am sending you all the possibilities for your problem, check either of these causes ----and than let me know if it is solved----
Power from the house
Check to see whether there's power getting to the dryer. Is it plugged in? Check for blown fuses or tripped circuit breakers--your dryer uses two fuses or circuit breakers. The dryer could tumble but not heat if only one of the two fuses is blown. If you have circuit breakers, one of the two circuit breakers can trip, even if the two for the dryer are connected.
Heating element
Often a dryer heating element burns out, but doesn't trip the circuit breaker or blow a fuse. The heating element is simply a long coil of special wire. You can check it for continuity with an ohm meter. No continuity means the element is bad and you need to replace it--electric heating elements aren't repairable.
Thermal fuse
On many dryers, there's a thermal fuse mounted to the exhaust duct inside the back cover panel. The fuse--which is about an inch long--is usually embedded in black resin and mounted in a white plastic housing. If the fuse has blown, you need to replace it. (You can't re-set it.)
Wiring
A common problem is for the main wiring connection from the house, at the dryer, to burn and break its connection. Because the dryer can still tumble with partial power, the connection may be only partially defective. You may need to replace both the power cord to the dryer and the terminal block inside the dryer that the wire is attached to.
10/24/2015 11:45:25 PM •
Maytag...
•
Answered
on Oct 24, 2015
What does error code U361 mean
A "U" code is a generally caused by an unbalanced load. If the dryer is level and has a medium size load causing the error, you may need to have the "Unbalance switch or control board" replaced. As with any electronics, unplug it for a few minutes to reset it and try again.
10/28/2014 9:42:02 PM •
Maytag...
•
Answered
on Oct 28, 2014