This is an older Jacuzzi
house breaker box did the breaker for this pump trip? usually they are on theyre own breaker in the main breaker panel
4/28/2017 5:15:30 PM •
Jet Plumbing
•
Answered
on Apr 28, 2017
Roots in sewer line
uh oh that's bad, you have roots growing in the sewer lines, more info is needed here
4/28/2017 5:10:23 PM •
Jet Plumbing
•
Answered
on Apr 28, 2017
PRIME A GOULD PUMP
whats your question how to prime the pump? if so at the bottom is a 3/4 inch plug screwed into it, or at top, once the pump is hooked up to the lines turn off the power, and unscrew the prime plug fill with water, then screw in tight DO NOT USE THREAD SEALANT THEN THROW THE POWER TO THE PUMP, of course house supply valve must be off 3/4 turn valve off until the line is primed then open the supply line to house slowly to supply the water to all the lines, NOTE WHEN YOU FIRST INSTALL A NEW PUMP, HAS TO BE PRIMED, HAVE TO HAVE SUPPLY LINES FROM WELL TO HOUSE CLOSED TO PRESSURE THE TANK AND TO FILL THE LINES.
4/28/2017 5:09:29 PM •
Jet Flo...
•
Answered
on Apr 28, 2017
Any suggestions when a newly installed utilitech pump won't turn off?
its sucking dry or your wiring is not right, or of course an airleak, or the prime is not good, did you fill the pump prime hole at the 3/4 plug on bottom.of pump, deep well pump do you mean submersible? if so and it is a deep well submersible there is a prime, its got to be an airleak in the line or the pressure tank is not pressured up to the specs, and the gauge
4/28/2017 5:04:10 PM •
Jet Plumbing
•
Answered
on Apr 28, 2017
How do l do to change the jet pump turbine and seal?
you mean the empellor ? and seal, it is a pain as the pump is sealed and don't normally go thru an empellor without going thru the motor life too, unless of course you sucked a rock up in there because of no screen at your gravel point, pumps are cheap and they live theyre life pretty well, if you need and empellor and and a seal chances are its worn out by a new one or you will have problems still
4/28/2017 5:00:10 PM •
Jet Plumbing
•
Answered
on Apr 28, 2017
Why isn't jet pump pumping?
Your suction line has an air leak, hence no suction , no prime. All fittings have to be perfectly tight and leakfree on intake side.
4/28/2017 4:52:36 PM •
Jet Plumbing
•
Answered
on Apr 28, 2017