We have Konica Minolta Bizhub 250 What does error C2557 mean

3 Answers

Zaheer Ahmed

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

  • Konica Minolta Expert 347 Answers
  • Posted on Sep 26, 2010
Zaheer Ahmed
Konica Minolta Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

President:

An expert whose answer got voted for 500 times.

Joined: Jul 02, 2009
Answers
347
Questions
2
Helped
289335
Points
719

Error code c2557 means "Auto Toner Density Control sensor abnormality" (ATDC)

Norman Weimar

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Konica Minolta Master 7,035 Answers
  • Posted on Dec 30, 2014
Norman Weimar
Konica Minolta Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: May 09, 2009
Answers
7035
Questions
2
Helped
1910567
Points
11959

Sir, Mam, When the developer was changed did the tech use a vacuum cleaner if so he may have destroyed the ATDC sensor. In service mode Clear counters first EXIT once THEN POWER OFF Master Power Rear left side (DO NOT EXIT ALL the WAY OUT OF SERVICE MODE), dump old developer, install new developer run F8. Do not run copies or prints before running F8 Remove Ethernet cable and FAX line to prevent any printing.

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

Ad

Ben

Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

  • Expert 108 Answers
  • Posted on Jul 29, 2014
Ben
Expert
Level 2:

An expert who has achieved level 2 by getting 100 points

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Vice President:

An expert whose answer got voted for 100 times.

Joined: May 12, 2010
Answers
108
Questions
0
Helped
89389
Points
277

Abnormally low toner detected TCR sensor.
Problem with the developer, toner sensor, or if a PM was done and the counters were not cleared property. Open and close front door to reset. If error returns, check developer unit.

1 Related Answer

hamzaskilltd

amir hamza

  • 318 Answers
  • Posted on Aug 07, 2010

SOURCE: Solution for error code c2557 konica minolta bizhub 250 machine

ADTC sensor failure

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Konica Minolta Bizhub C220. It has error code C2557 constant paper jam and faint black and white printout

What is error code c2557 on Konica c220?

Check the toner bottle to ensure that it is feeding toner into the sub hopper unit under the bottle. Sometimes users will insert the bottle incorrectly and not lock it properly in place...the lever on the front of the toner hopper for that bottle is moved down to the left to remove and insert the bottle.
Dec 28, 2010

Error code C2557 - Konica Minolta - Copytechnet

1helpful
1answer

How do I solve c2557 error ?

Hi
I found your error code and suggested remedies here:
Error Codes Konica Minolta bizhub 250 Code C2557
This site is very useful as by changing the drop down menus along the top of the page you can view other errors for your machine and for other models and makes. You can also use the link to get a pdf format Service Manual for your machine.
Hope this is helpful, if so would you please register that with Fixya
Cheers
1helpful
1answer

Errorc2557

It is my pleasure to guide you.


Konica Minolta 250 Error C2557 is Toner Density sensor problem

Problem: code C2557 - Abnormally low toner density detected Black TCR Sensor

Sounds like something a technician should take care of. Most of the information I could obtain says that the


Solution: Replaced 4038-R729-00 Hopper Drive Assy (C250 part compatible with C252 )

Good luck and please post back that you are successful, giving thumbs up, or if I can be more helpful.

7helpful
2answers

Konica bizhub 250 error c255c

there is no c255c code but if it is a c2555 c2556 c2557 or any other c255 code it may need a new image unit. please give more info
2helpful
1answer

My Minolta Bizhub-200 prntr. has a C2557 error code. How do I clear it?

Hello,
moz-screenshot.pngmoz-screenshot-1.pngC2557 - Abnormally toner detected black tcr sensor.

Reinstall image unit black
Reinstall toner cartridge
Change Image unit
Change toner carridge.

33helpful
3answers

Bizhub 350 error code c2557, how can i fix this?

This code happens if you replace drum without replacing developer. Both must be replaced at same time.
6helpful
1answer

Error c2557 konica minolta 250/NEC IT2530

Reset it, start it with the right door open, go to service mode, clear the counters for drum and developer and go to functions menu. Close the right door and start immediately the F8 function. It should work.
1helpful
2answers

Konica/Minolta biz 350 C2557 after replacing DV unit and drum F8

tha minolta di3510 developer unit looks the same as the unit for the konica minolta bizhub 350 but the toner sensor in the minolta unit uses a different voltage range for the toner sensor and it will throw this code make sure you have the correct unit for this machine also you can try this
go back into tech rep mode and change these settings:
select tech rep choice mode
select printer tab
select atdc sensor gain
set the value to about 165
then back all the way out to the ready screen and power the machine off then back on and replenish toner in the user management screen.
5helpful
1answer

Our bizhub-250 receives a C2557

hi,

open and close front door cover to reset error.

If it persists you have to execute (TCR Toner SUPPLY)

Tell me if you need to execute it.

Bye.
Not finding what you are looking for?

1,991 views

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7035 Answers

Cindy Wells

Level 3 Expert

6688 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...