C1183
Elevator motor ascent/
descent drive failure
• The elevator tray lower limit sensor (PC13) is not turned ON
even after the set period of time has elapsed after the main
power switch is set to ON.
• The elevator tray home position sensor (PC11) and elevator
top face detection sensor (PC12) are not turned ON even
after the set period of time has elapsed after the elevator
motor (M11) is energized.
• The elevator tray does not stop at the position for the specified
tray after the elevator motor (M11) is energized (beginning of
descent operation) and the elevator tray lower limit sensor
(PC13) is turned ON.
• The elevator top face detection sensor (PC12) is not turned
ON even after the set period of time has elapsed after the elevator
motor (M11) is energized (beginning of ascent operation)
when paper is being fed out.
×