Have a ge/maytag stackable unit. model# wsm2700dawww. is the tub suppose to rotate in a counter clockwise fashion while the agitator is going back & forth during the wash cycle?? Just replaced the transmission. The repair man that originally diagnosed the bad transmission said that the tub should remain stationary. As far as I remember, the tub has always rotated.
Sounds like the spin coil/brake solenoid is burnt out or broken. This is a coil situated on the motor plate under the machine with a lever attatched to it. When the machine goes into spin cycle, this solenoid pulls the brake away from the outer drum to allow the drum and agitator to spin together. The shaft that goes into this coil should move in and out freely. If tight, replace spin coil/brake solenoid.