Fuser unit is in good condition, but it has been stuck by the counters. Ps: there's no "menu" button, so, menu * 2 4 6 8 wont work.
SOURCE: Replace Fuser Reset
For the MFC 8860, I turned off the printer. I help down menu. I turned on the computer. It entered Maintenance mode. I typed in 88 (Parts Replacement.) I scrolled to the fuser, clicked ok. Then, I turned off the printer. When I turned the printer on, it said that I needed to replace my laser. I then turned the printer off, help down menu, turned the printer on, typed in 88 at the maintenance menu (parts replacement), scrolled down to laser, and hit ok. I then turned the printer on and off, and poof, now it works. I find it quite unscrupulous that I had a replace PF Kit1, replace Fuser, and replace laser messages all within one hour...
SOURCE: Brother 8460n Fuser Unit
Hit in sequence Menu,*,2,8,6,4
This will put it in maint. mode.
Press 88
That is parts counter reset, scroll down and hit ok on the part you want to reset the counter. :)
SOURCE: Reset maintenance counter
To reset the Maintenance counter yiu need to go into Config Mode.
Power on the printer while holding the 2 & the 6 button.
You will see the maintenence counter and can reset it from there.
SOURCE: need to reset the fuser counter
Hi there.
Download Service Manual here: http://nodevice.com/manual/Konica_Minolta_QMS_magicolor_7300_Service_Manualpdf/get690.html
and follow the instructions.
Regards.
SOURCE: I want to reset counters for fuser and transfer
Hi schoeller:
Hope this helps.
Replacing the transfer unit when it is not at end-of-life
If you replace the transfer unit when it is not at the end-of-life, for instance if it is defective,
you will need to reset the transfer unit count and then calibrate the printer, through the
control panel.
To reset the transfer unit count, do the following:
1. Press MENU to enter the MENUS.
2. Press down arrow to highlight Configure Device.
3. Press check to select Configure Device.
4. Press down arrow to highlight RESETS.
5. Press check arrow to select RESETS.
6. Press down arrow to highlight RESET SUPPLIES.
7. Press check to select RESET SUPPLIES.
8. Press down arrow to highlight NEW TRANSFER KIT.
9. Press check to select NEW TRANSFER KIT.
10. Press down arrow to highlight YES.
11. Press check to select YES.
To calibrate the printer, do the following:
1. Press MENU to enter the MENUS.
2. Press down arrow to highlight Configure Device.
3. Press check to select Configure Device.
4. Press down arrow to highlight PRINT QUALITY.
5. Press check to select PRINT QUALITY.
6. Press down arrow to highlight CALIBRATE NOW.
7. Press check to select CALIBRATE NOW.
8. Wait for the printer to calibrate.
The transfer unit count is reset and the printer is ready to use.
To reset the fuser count
1. Press MENU to enter the MENUS.
2. Press down arrow to highlight Configure Device.
3. Press check to select Configure Device.
4. Press down arrow to highlight RESETS.
5. Press check to select RESETS.
6. Press down arrow to highlight RESET SUPPLIES.
7. Press check to select RESET SUPPLIES.
8. Press down arrow to highlight NEW FUSER KIT.
9. Press check to select NEW FUSER KIT.
10. Press down arrow to highlight YES.
11. Press check to select YES.
The fuser count is reset and the printer is ready to use.