Coffee Makers & Espresso Machines Logo

Related Topics:

N
Neal Wedding Posted on Aug 13, 2018
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

Krups EA8250 starts up, but preheats only for a second and thinks it is pre-heated. It will run through a full brew cycle, but cold, watery espresso comes out since it's not using hot water.

Initially, I could get the machine to heat for steam, then brew espresso, but that is not working now. I have the machine apart and would like to know how to troubleshoot whether the problem is the controller or the thermoblock. It looks like the thermostat is built into the thermoblock with no way to replace it separately.

2 Answers

Nikolaos Astyrakakis

Level 1:

An expert who has achieved level 1.

  • Contributor 1 Answer
  • Posted on Nov 05, 2021
Nikolaos Astyrakakis
Contributor
Level 1:

An expert who has achieved level 1.

Joined: Nov 05, 2021
Answers
1
Questions
0
Helped
1358
Points
3

Today I fixed mine krups ea8108 by changing the heatblock NTC... With a 3D printer NTC 100K ohm....

I just screw the new NTC together with heat blow fuses... See pictures...

NTC can be unglued / removed from the heat boiler block with a screwdriver...

Stock NTC is 100K ohm in case you wonder...

My problem was that machine didn't preheat on power on... it was heating only with steam button...

Simple replace ntc with 3d printer ntc or any other 100K ohm ... Solder it to normal connector cables and done... Final result:

Krups EA8250 starts up, but preheats only for a se - img_20211105_191803-jbeb5hgykfzakwbmwhtk10tx-6-0.jpg Stock ntc:


bKrups EA8250 starts up, but preheats only for a se - img_20211105_191806-jbeb5hgykfzakwbmwhtk10tx-6-4.jpg0211105_191806-jbeb5hgykfzakwbmwhtk10tx-6-4.jpg" alt="img_20211105_191806-jbeb5hgykfzakwbmwhtk10tx-6-4.jpg" class="h_mi" Krups EA8250 starts up, but preheats only for a se - img_20211105_191759-jbeb5hgykfzakwbmwhtk10tx-6-7.jpgconnector cables: New ntc:


img_20211105_191806-jbeb5hgykfzakwbmwhtk10tx-6-7.jpg


img_20211105_191747-jbeb5hgykfzakwbmwhtk10tx-6-8.jpg

Ross Keen

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Krups Master 1,365 Answers
  • Posted on Nov 23, 2018
Ross Keen
Krups Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: Jun 20, 2007
Answers
1365
Questions
0
Helped
583405
Points
2445

If the thermoblock itself is the problem then I'd expect to read the element as open circuit because that's the only electrical part it has. The NTC that reads the temp is glued on with a special heat resistant glue, possibily it could be unstuck. The NTC's did suffer from solder failure where the wire terminal is. The NTC is only available as a new part complete with the thermoblock.

Ad

5 Related Answers

Anonymous

  • 1089 Answers
  • Posted on May 22, 2011

SOURCE: My espresso machine doesn't heat

Hi
If it heats with the steam switch, its your brew thermostat. If it doesn't, its your heating element.

Ad

Anonymous

  • 449 Answers
  • Posted on Sep 24, 2008

SOURCE: Cleaned brew unit, then reinserted

hi!!
maybe you check the pump
and clean
or may a replacement

Anonymous

  • 1 Answer
  • Posted on Feb 06, 2009

SOURCE: Delonghi EC 155 general help

You don't have to wait 15 mins. just a few minutes, then run some hot water to warm up the portafilter and dry it up, fill it up with coffee and when you get the gree light again, make your espresso . You will have to have a good fine coffee and make sure to pack the coffee really good and don't leave any around the edges , so could make a good seal. If you have steam coming out of the machine , is maybe to hot and is ready to brew . Cool down the machine after use, run water through it and let the steam out of the nozzle.

Anonymous

  • 22 Answers
  • Posted on Oct 19, 2009

SOURCE: Krups model KM7005 water wont heat

Mine had the same problem ... all the lights are on, but no heating on the plate, and no dripping of water.

After a weekend on the workbench, I've mastered this machine. The KM7005 has 2 x MicroTemp G4 thermal cutoff (TCO) fuses which interrupt the Live line, for overheat protection. Mine didn't overheat per se, but the TCO blew anyway. Not reset-able ... need to be replaced with a soldering iron. I'll be happy to advise you to fix this, or fix it for you. Write me at [email protected].

Anonymous

  • 1 Answer
  • Posted on Nov 19, 2011

SOURCE: Recently my Krups 4050 espresso machine starting b...

It needs a new flow meter. I replaced the one in mine and now it works fine. I took the old one apart and the little magnet inside is a ferrite magnet which rusts over time when it comes in contact with water ( duh). If the new one does this I am going to just replace the little magnet with a rare-earth magnet which will cost about $1 or less and shouldn't rust out. I am wondering if the company changed the magnet in the new flow meter so this doesn't happen or if planned obsellesants, just last long enough to get it out of warranty, is the company's motto. The new flow meter was around $30 when the added the $9 for shipping.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

Krups Ea8250 not heating. Getting automatic maintenance then pull plug and put back in.

open the machine, look at the wiring to the water heater. 1 cable is loose in the rubber/PVC cap. you have to solder it again.
0helpful
1answer

How to reset brew counter on Krups EA8250

I found this on the internet:

Try this, remove the tank, the drip tray, the bin on the side and the sliding thing above the bin. Hold down the on and steam buttons while plugging the machine into a live socket, it's either that or the same again but holding down the on button and the program button while plugging it in. You will get a screen that says something like " Remis a something vende" which is French for put it into sale state, you choose "Oui" for yes
0helpful
1answer

How do I reset the brew counter on my Krups EA8250?

Found on the internet:

Try this, remove the tank, the drip tray, the bin on the side and the sliding thing above the bin. Hold down the on and steam buttons while plugging the machine into a live socket, it's either that or the same again but holding down the on button and the program button while plugging it in. You will get a screen that says something like " Remis a something vende" which is French for put it into sale state, you choose "Oui" for yes Hope this helps
0helpful
1answer

Error code 1 krups ea8250

http://www.fixya.com/support/t24997792-krups_error_code_01
0helpful
1answer

What are the instructions for preheat after turning our bunn coffee maker off over night - there is not off switch, plug in only

* Bunn model # for specific solutions.
* Most Pro/Office models have a pre-heated tank.
* Most models (Without Vacation or heater switch) will be heated all the time.
* Care must be taken to keep the inner tank filled.
* Pour cold water into fill tray till water comes out of the brew basket.
* Water will stop coming out of brewer once the tank has been topped off.
* If pot is not able to brew after 20 mins of pre-heating. Then call for service.
* Note; most office and Pro machines used in food establishments are from coffee vendors. The larger machines should be serviced by qualified Bunn service techs.
* Contact your coffee vendor or Bunn service ctr for advice.
Aloha, ukeboy57
0helpful
1answer

KRUPS EA8250: Machine was going through cleaning cycle and stopped at the rinsing phase and displayed "Error Code 01". Any suggestions?

Error code 01 accompanied by that noise points at the distributor being faulty. The distributor is the electronic tap that directs water to the ram to compress the grounds in the boiler and then redirects it to the brewing chamber to make the coffee, then to steam, then to rinse. It's the sort of item you just replace because it's quite a large job to change it anyway, not the sort of repair you want to be doing over and over trying not to spend money on the part.
0helpful
1answer

Krups EA8250 Displaying "Filling of the machine necessary" with full water reserve and hopper.

I suggest that you use the commands to "close the machine" for transport and then re-start it as if it was new. I had to get rid of my EA8250 after only 2 years as mine stopping working as well. I tore it apart and saw a lot of wear for such as short time. My grinder also stopped. KRUPS says you cannot use Oily beans but only after you buy the machine.
0helpful
1answer

When Krups ea8250 turns on says heating then unplug sign

It seems like it must be detecting an error of some sort. Maybe the boiler is not heating, maybe the pump is not pumping, only testing will reveal the cause.
1helpful
1answer
Not finding what you are looking for?

1,368 views

Ask a Question

Usually answered in minutes!

Top Krups Coffee Makers & Espresso Machines Experts

Mike Cairns
Mike Cairns

Level 3 Expert

3054 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Paul Carew

Level 3 Expert

3808 Answers

Are you a Krups Coffee Maker and Espresso Machine Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...