Office Equipment & Supplies Logo

Related Topics:

thabang mollo Posted on Feb 27, 2018
Answered by a Fixya Expert

Trustworthy Expert Solutions

At Fixya.com, our trusted experts are meticulously vetted and possess extensive experience in their respective fields. Backed by a community of knowledgeable professionals, our platform ensures that the solutions provided are thoroughly researched and validated.

View Our Top Experts

How do I rest a drum on konica minolta C554e

I have replaced a drum on Konica Minolta C554e but its still showing replenish drum unit

1 Answer

Norman Weimar

Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

  • Konica Minolta Master 7,035 Answers
  • Posted on Mar 04, 2018
Norman Weimar
Konica Minolta Master
Level 3:

An expert who has achieved level 3 by getting 1000 points

Superstar:

An expert that got 20 achievements.

All-Star:

An expert that got 10 achievements.

MVP:

An expert that got 5 achievements.

Joined: May 09, 2009
Answers
7035
Questions
2
Helped
1911988
Points
11959

Then the drum you replace is not new there is a chip on it which tell the copier its new

Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f

5 Related Answers

Dan Hudson

  • 119 Answers
  • Posted on Nov 18, 2008

SOURCE: Konica Minolta Magicolor 2400W drum cartrige-how to replace?

Did you buy a whole new drum unit, or just change the cartridge? If so, the fuse may still be blown. Also, you may need to empty the spent toner out of the old cartridge.

Ad

Anonymous

  • 62 Answers
  • Posted on May 27, 2009

SOURCE: Hi In our office Konica Minolta C250 ,it show message mulfunction. error:- c0206

Hi,
C-0206 relates to tray 3.
With the copier turned on do the following
Open paper tray 3, remove paper, close tray, open then shut front door, load paper into tray 3 - hey presto!!
If the fault comes back you could have paper stuck behind the tray or have a defective lift up motor.
Regards
Taminol

Anonymous

  • 51 Answers
  • Posted on Aug 30, 2009

SOURCE: konica minolta bizhub

whot is the error code and whot model of bizhub u have???

Anonymous

  • 13 Answers
  • Posted on Sep 13, 2009

SOURCE: Reset Chip on Konica Minolta 8031 Imaging Unit

I can provide you with a programmer to reset the chip. They are only about $500-$700. Still interested?

Anonymous

  • 99 Answers
  • Posted on Dec 12, 2009

SOURCE: how to replace drum unit for a konica-minolta

Press left side top cover release.Open top cover,open cartridge >open drum unite.

Ad

Add Your Answer

×

Uploading: 0%

my-video-file.mp4

Complete. Click "Add" to insert your video. Add

×

Loading...
Loading...

Related Questions:

0helpful
1answer

I HAVE A KONICA MINOLTA 190F COPIER PLS DIRECT ME ON HOW TO COUPLE THE DRUM ITSELF TO THE HOLDER

Please refer to the service manuals and this.

Replacing a Drum Unit


Konica Minolta Manuals

https://manuals.konicaminolta.eu > contents











After Drum Unit replacement step 1 has been completed, check that the red-circled lock is located at the position indicated by a dashed line, then execute step ...















Konica Minolta REGIUS 190 Service Manual






ManualsLib

https://www.manualslib.com > ... > REGIUS 190











View and Download Konica Minolta REGIUS 190 service manual online. REGIUS 190 medical equipment pdf manual download. Also for: Dd-941.







Konica Minolta - Regius 190 Community, Manuals and ...






MedWrench

https://www.medwrench.com > equipment > konica-m...











Konica Minolta - Regius 190 by Konica Minolta. Konica Minolta - Regius 190. Forums ... Regius 190 Service Manual. SERVICE COMPANIESView All Computed Radiography ...







Konica Minolta Regius 190 (DD 941) Service Manual






Internet Archive

https://archive.org > details > manual_Konica_Minolta...











May 20, 2020 - KONICA MINOLTA. DIRECT DIGITIZER. REGIUS MODEL 190. (DD-941). SERVICE MANUAL. KONICA MINOLTA MEDICAL & GRAPHIC, INC.



..https://www.youtube.com/watch?v=lqfANSFl6Io



































0helpful
1answer
0helpful
1answer
0helpful
3answers

Konica Minolta BizHub C252 - pale colors on the long side

Konica Minolta BizHub C252 Repair Questions,... - Fixya

www.fixya.com > Forum > Printers & Copiers > Konica Minolta
Konica Minolta BizHub C252 - pale colors on the long side · Konica Minolta. ... I have a Konica C250 machine which cannot print red color at all. I had changed ...

Konica Questions answered here ' FixYourOwnPrinter

www.fixyourownprinter.com/posts/40820
Aug 22, 2008 - On the right hand side of the drum (the part that has the large green handle) that easily slides out. There is a ..... I have konica minolta bizhub c252 colour printer. ... The K light came on a long time ago and is constant on now.

How to clean the drums/i units on the konica minolta number ...

? 0:28
https://www.youtube.com/watch?v=eD8HdNq0MlE
Nov 23, 2011 - Uploaded by Tennants Nottingham
How to clean the drums/i units on the konica minolta number plate printer ... Fix or repair color laser printer with fading, lightprint, or lines samsung clp 300 ... Imaging Unit Reset for Konica Minolta Bizhub C203 / C253 / C353
0helpful
1answer

Konica minolta bizhub C253 is showing me trouble code C- 2556. What should I do to pix this problem

Konica-Minolta bizhub C253 Trouble Error Codes List page 4

Code C2556
Abnormally high toner density detected yellow TCR sensor
• TC ratio in the developing machine, which is determined by toner replenishing amount control mechanism, is 11 % or more for a given number of times consecutively. • When the connector of the TCR sensor is disconnected.
Solution:
1 Reinstall imaging unit. 2 Reinstall toner cartridge. 3 M3, M4 operation check (At this time, IU must be non-installation.). 4 Change imaging unit. 5 Change PRCB
Extract from:
http://www.printcopy.info/?l=en&mod=free&chap=erc&brand=Konica-Minolta&model=bizhub%20C253&page=4
0helpful
1answer

Konica C554 printing colors faded. Doesn't need new cartridges. What can I do to fix it?

Hi Macalla,
The only thing that comes to mind is possibly the drum unit needs replacing. These machines are normally under a service contract. You should have gotten either a drum unit needs replacing message of toner needs refilling message on the screen. The drum replacement idea is just a GUESS!!. see link below

http://kmbsmanuals.konicaminolta.us/c554e/contents/id11-_101378852.html
1helpful
2answers

Konica/Minolta biz 350 C2557 after replacing DV unit and drum F8

tha minolta di3510 developer unit looks the same as the unit for the konica minolta bizhub 350 but the toner sensor in the minolta unit uses a different voltage range for the toner sensor and it will throw this code make sure you have the correct unit for this machine also you can try this
go back into tech rep mode and change these settings:
select tech rep choice mode
select printer tab
select atdc sensor gain
set the value to about 165
then back all the way out to the ready screen and power the machine off then back on and replenish toner in the user management screen.
1helpful
2answers

To change opc drum in konica minolta

To Change OPC DRUM UNIT in KONICA MINOLTA 2300 w

Switch Printer Off

Open Front Door Cover

Remove Waste Toner Box

Lift Transfer Belts Blue Knob until it's placed at 11 o'clock. (it's directly behind the waste toner box)

The OPC DRUM UNIT is directly under the BLUE KNOB

SQUEEZE HANDLE and PULL OUT the OPC UNIT

Be VERY CAREFUL NOT TO SCRATCH THE GREEN COLOURED ROLLER on the OPC DRUM UNIT.

Replace new OPC DRUM and turn BLUE KNOB of TRANSFER BELT back to 7 o'clock position

Replace Waste Toner Box, Close Front Cover and Switch On.

Status Display will show OPC Drum at 100%

(You can also replace the fuse in the OPC DRUM UNIT and save yourself HUNDREDS on a new one)
I posted this on another solve problem previously, worth looking at.
Not finding what you are looking for?

585 views

Ask a Question

Usually answered in minutes!

Top Konica Minolta Office Equipment & Supplies Experts

Norman Weimar
Norman Weimar

Level 3 Expert

7035 Answers

Cindy Wells

Level 3 Expert

6688 Answers

ZJ Limited
ZJ Limited

Level 3 Expert

17989 Answers

Are you a Konica Minolta Office Equipment and Supply Expert? Answer questions, earn points and help others

Answer questions

Manuals & User Guides

Loading...