I tried to reset with the micro switch in the front under the imaging unit but still error persist.
C0200 - Cyan PC Drum Charge Corona Malfunction. Did you mess with this imaging unit? You won't be able to reset if the malfunction is still present.
---------------------------------------------------------------
Konica Minolta Error Codes & Solutions - http://www.kmcodes.com
Drum, Transfer Belt and Fusing Unit Firmware Reset - http://www.bizhubreset.com
Drum and Toner Chip Reset - http://www.chipreset.eu
Transfer Belt and Fusing Unit Reset Kit - http://www.resetkit.eu
SOURCE: Bizhub c350 will not scan to hdd
Easiest way is to change to SMB scanning which will give you direct scanning to PC or server. Create a new address in the machines address tab in the browser add the (must be a fixed) ip address of the machine it is going to with the folder name, user name and password and it will work a treat.
SOURCE: Konica Minolta C353 has a C4551 error, how do I fix it?
try replacing the imaging unit with a new one not a reset imaging unit
SOURCE: c350 malfunction code c-0501
After replacing the fuser unit, if you got a c0501 code you must open the front door where the toner is. On the right side (hinge side) next to the black toner and drum unit there is a plastic pannel/cover. In the lower portion of that pannel there is a hole where a trouble reset switch is loacted. With a flashlight you may be able to see it. You are ment to use a thin screw driver or the like to push the button. You do this while the machein is on and desplaying the code. As soon as you press the button the copier will clear the code and start warming up. Thats it! If you are un certin of the button placement you can take out three screws from the pannel and loosen one screw from the pannel above it and and pull the pannel off the unit. You will see the board and it is the button on the (left), as there are two of them. Tho you only have access to the one thru the cover.
SOURCE: Replacing Image Transfer Roller Unit & Paper Dust/Ozone Remover
hi this unit located in the RIGHT DOOR
SOURCE: how to reset the copier after installing the
Normally it has no need for reseting.
In the moment you put the new image unit it resets the counter life, although you can reset by holding down the trouble reset button and in the screen you will see trouble reset.
touch it and switch in and off the machine with the main power button.
213 views