SOURCE: konica minolta bizhub pro c6500 error c2452
Toner low density abnormality
When the developing motor/M (M21) is ON, the maximum detection value of TCR sensor/ M (TCRS/M) is the specified value and the difference
between the maximum detection value and the minimum detection value is over the specified value.
Reset your Toners and Imaging units for Minolta Bizhub and CF series.
http://www.chipreset.eu
SOURCE: konicaminolta bizhub pro c6500
its a 24Volt error. It usually means replacing the ADU drive board. no way to cheat or disable it/
SOURCE: what does code 2454 mean on the konica minolta
Developing motor for the Black, working in conjunction with Toner Control Sensor.
Btw, I’m available to help over the phone in case u need at https://www.6ya.com/expert/normanj_7893313f0751935f
SOURCE: Have a konica bizhub c6500
C 2861= Gamma correction/Y aborted. Patch output voltage is high.
Possible causes: Printer control board (PRCB) Developing unit/Y
PGC sensor (PS11)
1,914 views
Usually answered in minutes!
×