U-Line Refrigerator Ice Maker - Page 4 Questions & Answers
Mini fridge-ice maker stopped cooling. Cleaned
If it is running but not cooling, I"ll clean the condenser first then make sure the condenser fan motor is running, if the condenser fan motor is not running, re place it with new one, or if compressor and condenser fan motor are running then it will be sealed system problem, if it is not cover by Warr. it is not worth to fix it.
3/2/2010 5:31:25 AM •
U-Line...
•
Answered
on Mar 02, 2010
In stalled new compressor . ice maker will not
I'm not sure what the problem may be but you could try calling All
Seasons RV Appliance Parts & Service. There number is
1-800-344-0673 they have helped me in the past. That and there tech
calls are free so it wouldn't hurt to give them a call.
2/16/2010 8:56:57 PM •
U-Line...
•
Answered
on Feb 16, 2010
I have a u-line ULN-WH95TP-03 THAT WILL FREEZE ICE
Your thermostat is what advances your icemaker. You have 3 wires. When it calls for freeze then yellow(2) and blue/black(3) is closed. When that is satisfied the compressor and fan cycles off then the yellow(2) and red(1) is closed. This calls for the icemaker to advance. Red goes to icemaker, yellow is common, and blu/black is for the fan and compressor.
Hope this helps you. I would replace the thermostat
2/13/2010 10:56:07 PM •
U-Line...
•
Answered
on Feb 13, 2010
We have the WH95TP unit on our boat. It has worked
Was the unit running when it was warm? If it was then you need a tech to look at the sealed system. If it wasnt running then you need to adjust the icemaker ejector blade so its straight up (12 oclock) Thats when it will allow the compressor to come on.
10/8/2009 4:05:12 AM •
U-Line...
•
Answered
on Oct 08, 2009
We have had the ice
Locate the ice maker speed control, either a dial or a lever, and set it to "medium".
9/6/2009 3:20:11 PM •
U-Line...
•
Answered
on Sep 06, 2009
My refrigerator ice maker does nt make ice . its
If now water in the mold of the icemaker then what is the temperature in the bucket? It could be the thermostat just isnt being satisfied. Depending on your model you may have 2 thermostats. If its not cooling(10-15 degrees) It could be cleaning the condenser. Or a sealed system problem.
8/16/2009 11:04:51 PM •
U-Line...
•
Answered
on Aug 16, 2009
Can the refg.be re-wired?
U-lines needs the icemaker to work properly. By doing what you did you would void all warranty. The controls are in the icemaker so the original parts would not work the way you want it to.
8/7/2009 6:46:31 PM •
U-Line...
•
Answered
on Aug 07, 2009
Will the refrigerator work if the ice machine is
You need to have the icemaker assembly in the unit. Now unless you are talking a clrco2075 you have to hookup the water. If its a regular icemaker then by lifting the arm everything should work. The icemaker has sensors in it and thats why you need the icemaker in place. What model do you have? Just to be sure, some models you have to program the icemaker to stay off.
7/17/2009 4:34:48 AM •
U-Line...
•
Answered
on Jul 17, 2009
Uline combo unit. Condensor fan will not run and
You just answered your question. If no fan is running then the compressor will overheat and the compressor goes off on overload. Do you have the evaporator fan running? If yes then replace the condensor fan. Both fans will run at the same time. If the evap fan is not running then the unit must be in defrost. Since its a hotgas defrost the compressor will run.
Hope this helps
7/15/2009 2:13:51 PM •
U-Line...
•
Answered
on Jul 15, 2009
Not getting water to ice maker or water despenser
1st make sure the water is on. Then advance the icemaker. What model do you have. If you dont have a electrical display then remove the cover and turn the smaller gear with a 5/16 screw counter clockwise. The ejector blade will get to 2 oclock when it will go on its own. When the ejector blade reaches 10 oclock then it will call for water. U-line icemakers have to reach temperature before it advances the icemaker. Again what model is it?
6/30/2009 9:06:28 PM •
U-Line...
•
Answered
on Jun 30, 2009
Ice maker will not harvest
As crazy as this sounds, turn the temp control a little warmer (counter clockwise). On this model, this control needs to switch to harvest the ice. A warmer setting should fix this issue.
Dean
You can also go to:
www.u-lineservice.com
6/6/2009 6:03:56 PM •
U-Line...
•
Answered
on Jun 06, 2009
U-Line combo 75 not getting cold
hi there,
i have some procedure in troubleshooting a ref., as follows:
1. check if the compressor will run when you plug the ref in the outlet/power.
a. if the compressor run and it will not produce the cold or heat. then the problem is, the system of your ref. has a leak. it lost all the freon charge into the system. find a near service center in your area.
b. if the compressor run and it stop. unplug your ref. from power.
- check the capacitor if it is ok, using a multi tester. by determining a good capacitor in resistance test at 100 kilo ohms or 10 kilo ohms the pointer will deflect to right and it will slowly going to left or a higher rating. bad ca[pacitor pointer steady in zero position or infinite.
- but if the capacitor is ok then some trouble in mechanical parts inside the compressor. specially when you turn on your ref. you feel some surge power from the case of the ref. find a near service center in your area. if you need to replace the compressor and some parts of it.
c. if the compressor will not run, unplug your ref from power and then check the follow:
- check the compressor resistance by using a multi tester, open the terminal box of the compressor. have some checklist in the terminal setting that has a letter symbol R (running) connected to what color of wire, same also with S (start) and C (capacitor) check in its terminal resistance.
6/6/2009 4:28:57 AM •
U-Line...
•
Answered
on Jun 06, 2009
Ice maker water leak
What is the model? This sounds like it would be the water switch or timing motor in the icemaker is sticking. My suggetion is to replace the faceplate on the icemaker.
6/1/2009 3:39:11 PM •
U-Line...
•
Answered
on Jun 01, 2009
Sometimes unit will not start
Temp Control unit needs to be replaced - approx $75. This unit has a pre-set temp control unit which triggers the compressor/cooling fan to come on when the temp reaches its set parameters. When it doesn't function, you get the stated problem.
5/20/2009 3:50:01 AM •
U-Line...
•
Answered
on May 20, 2009
Problem with ice maker
Christy
Depends on the model. BI models or co29 the setting is warmer to make more ice.co2075 you have 2 tstats. So the icemaker control is seperate.What model do you have
5/20/2009 3:40:09 AM •
U-Line...
•
Answered
on May 20, 2009
U-Line Model WCM48
You can try to advance your icemaker by removing the white cover on your icemaker and turn the smaller gear counterclockwise to advance the icemaker. When the icemaker starts wait until the ejector blade gets to 10 oclock position this is where it calls for water. The test would be unplug the coil on the valve and put a meter lead on each one. If you see 120 volts then replace the valve. If you dont see it it could be the water switch inside the head of icemaker.
5/18/2009 11:57:34 PM •
U-Line...
•
Answered
on May 18, 2009
Water inlet valve leak
Leaking out of the watervalve I would just replace it.Make sure the connections are on good.
5/14/2009 3:14:47 AM •
U-Line...
•
Answered
on May 14, 2009
U-Line clear Icemaker clr2160 cube shape
Hi Joe
That is normal. You will get that dimple because the grid is shaped that way. You can try adjusting the thickness. Hold the up arrow then press the down arrow 3 times,then release the up arrow last.You should see a number 0-5 or 0 to -5. when that happens use the up arrow to 3 then press the light key. This should take it back to ice on the display. Wait 24 hours and check the ice.
5/14/2009 3:13:14 AM •
U-Line...
•
Answered
on May 14, 2009