SOURCE: 93 Dyna low rider fork oil.
your local hd shop should be able to answer this for you as its a mesured amount and to much or too little will make the bike not handle right
SOURCE: Add transmission fluid to 2001 Harley dyna low rider
the tranny plug is behind the oil spout its usually a big allen head bolt. You should use a quality oil like AMSOIL 20W50 motorcycle oil or AMSOIL gear oil. I have the 20W50 in mine and really like the benifit of not having a pultrolium product in my bike. You can get the AMSOIL online a http://hbsynlube.com/sales. You'll beglad you changed it.
SOURCE: What is the fork oil capacity for a 2004 Dyna Low
If I am not mistaken. You will need ten ounces per side ounce you have completely drained them
SOURCE: how to change primary chain tension on 2007 Harley
Sorry, not up on new hogs but I think you remove plate off outer primary,it's got the foot peg mounted on it.Look through hole and you'll see the bolt that holds the chain support unit.Carefully loosen bolt and pry up or down,tighten or loosen, tension.You don't have belt right? some newer ones do.If you want hi-tech and yours doesn't have one already remove the outer primary and replace the "skidplate" adjuster with a roller type.Makes things quiet.There is room in the hole to check that you don't get chain too tight.
SOURCE: 2006 harley dyna charging at low speed, not at high rpms
This used to be a common problem back in the days of generators but I've not heard of this since Harley went to the alternator systems in 1970. It is unusual to say the least.
The first thing I'd do is have my battery tested. This is simply good procedure anytime you are experiencing a charging system problem.
Next, check the output of your alternator. To do this, you'll need a DVOM, digital volt ohm meter. Unplug the voltage regular at the front of your engine case close to the oil filter. Now, put your DVOM into "Voltage", "AC", Range 50 volts or better. Now, with the engine running, put one lead from the meter to one of the pins in the plug in the engine case. Put the other lead in the other pin. Rev the engine up to about 2000-2500 RPM. You should read at least 30 Volts AC. You must have the meter in the AC positon because an alternator puts out alternating current. Your regulator converts it to Direct Current voltage for the charging the battery and reduces the voltage. If you are reading thirty volts or better, I would suspect the Voltage Regulator is your problem.